N NEXUS MOLECULAR LABS ANALYTICAL SERVICES ISO/IEC 17025 Accredited · CAP Certified · Health Canada Licensed

Certificate of Analysis

SNAP-8 (10mg)

Report No: NML-SNAP8-260619-001 Analysis Date: 2026-06-22 Report Issued: 2026-06-26
Sample Identification
Compound SNAP-8 (10mg) Client Numira Peptides  ·  numira.cc
CAS Number868844-74-0Date Received2026-06-18
Molecular FormulaC40H70N14O16Date Tested2026-06-22
Molecular Weight 1075.3 g/mol PubChem CID11751549
Lot Number NML-SNAP8-260619 Test Methods HPLC-UV · ICP-MS · Kinetic LAL
Appearance White lyophilised powder Date Reported 2026-06-26
HPLC-UV Purity & Content Analysis
10mg
Ordered Amount
9.89mg
Measured Amount
98.71%
Purity (HPLC-UV)
98.7%
Recovery
Fig. 1 — HPLC-UV Chromatogram (214 nm)  ·  Run: NML_SNAP8_SNAP8-260619_1.d
mAU 0 300 600 900 1200 0 2 4 6 8 10 12 Time [min] SNAP-8 5.42 min
SNAP-8 (10mg) vial
APPEARANCE
#Retention Time (min)Area% AreaAssignment
12.601.3E+020.64Unknown impurity
25.424.010E+0498.71SNAP-8
38.201.2E+020.51Unknown impurity
Bacterial Endotoxin Test (USP <85>)
MethodResultSpecificationVerdict
Kinetic LAL (USP <85>)< 0.125 EU/mL≤ 0.125 EU/mLPASS
Elemental Impurities (USP <233> / ICH Q3D)
ElementMethodResult (ppm)Limit (ppm)Verdict
Arsenic (As)ICP-MS< 0.0012.1PASS
Cadmium (Cd)ICP-MS< 0.0010.5PASS
Lead (Pb)ICP-MS< 0.0010.5PASS
Mercury (Hg)ICP-MS< 0.0013.0PASS

Note: Peptide samples may contain counter-ions (TFA, acetate) and excipients (mannitol, sucrose) used as lyoprotectants and pH buffers. These are not detected by UV and are not classified as impurities under USP <233>.

Analysis Performed by
Dr. M. Chen, Ph.D. (Analytical Chemistry)
Senior Analytical Chemist · Nexus Molecular Labs
info@nexusmolecularlabs.com