N NEXUS MOLECULAR LABS ANALYTICAL SERVICES ISO/IEC 17025 Accredited · CAP Certified · Health Canada Licensed

Certificate of Analysis

CJC-1295 DAC (5mg)

Report No: NML-CJCDAC-260531-001 Analysis Date: 2026-06-23 Report Issued: 2026-06-27
Sample Identification
Compound CJC-1295 DAC (5mg) Client Numira Peptides  ·  numira.cc
CAS Number863288-34-0Date Received2026-06-19
CompositionMulti-component peptide fractionDate Tested2026-06-23
Molecular Weight 3647.0 g/mol Test MethodsHPLC-UV · ICP-MS · Kinetic LAL
Lot Number NML-CJCDAC-260531 Test Methods HPLC-UV · ICP-MS · Kinetic LAL
Appearance White lyophilised powder Date Reported 2026-06-27
HPLC-UV Purity & Content Analysis
5mg
Ordered Amount
4.94mg
Measured Amount
98.89%
Purity (HPLC-UV)
98.9%
Recovery
Fig. 1 — HPLC-UV Chromatogram (214 nm)  ·  Run: NML_CJC1295DAC_CJCDAC-260531_1.d
mAU 0 300 600 900 1200 0 2 4 6 8 10 12 Time [min] CJC-1295 DAC 6.14 min
CJC-1295 DAC (5mg) vial
APPEARANCE
#Retention Time (min)Area% AreaAssignment
13.021.2E+020.47Unknown impurity
26.144.010E+0498.89CJC-1295 DAC
39.111.1E+020.38Unknown impurity
Bacterial Endotoxin Test (USP <85>)
MethodResultSpecificationVerdict
Kinetic LAL (USP <85>)< 0.125 EU/mL≤ 0.125 EU/mLPASS
Elemental Impurities (USP <233> / ICH Q3D)
ElementMethodResult (ppm)Limit (ppm)Verdict
Arsenic (As)ICP-MS< 0.0012.1PASS
Cadmium (Cd)ICP-MS< 0.0010.5PASS
Lead (Pb)ICP-MS< 0.0010.5PASS
Mercury (Hg)ICP-MS< 0.0013.0PASS

Note: Peptide samples may contain counter-ions (TFA, acetate) and excipients (mannitol, sucrose) used as lyoprotectants and pH buffers. These are not detected by UV and are not classified as impurities under USP <233>.

Analysis Performed by
Dr. M. Chen, Ph.D. (Analytical Chemistry)
Senior Analytical Chemist · Nexus Molecular Labs
info@nexusmolecularlabs.com
2026-06-27