N NEXUS MOLECULAR LABS ANALYTICAL SERVICES ISO/IEC 17025 Accredited · CAP Certified · Health Canada Licensed

Certificate of Analysis

BPC-157  ·  10 mg

Report No: NML-BPC-250501-001 Analysis Date: 2025-05-01 Report Issued: 2025-05-07
Sample Identification
Compound BPC-157  (Body Protection Compound-157) Client Numira Peptides  ·  numira.cc
CAS Number 137525-51-0 Date Received 2025-04-28
Molecular Formula C₆₂H₉₈N₁₆O₂₂ Date Tested 2025-05-01
Molecular Weight 1419.53 g/mol Date Reported 2025-05-07
Lot Number NML-BPC-250501 Test Methods HPLC-UV · ICP-MS · Kinetic LAL
Appearance White lyophilised powder PubChem CID 9908089
HPLC-UV Purity & Content Analysis
10 mg
Ordered Amount
9.98 mg
Measured Amount
99.05%
Purity (HPLC-UV)
99.8%
Recovery
Fig. 1 — HPLC-UV Chromatogram (214 nm)  ·  Run: NML_BPC157_250501_1.d
mAU 0 300 600 900 1200 0 2 4 6 8 10 12 Time [min] Time [min] 2.14 min 4.62 min BPC-157 5.82 min 8.37 min
BPC-157 10mg vial
APPEARANCE
# Retention Time (min) Area % Area Assignment
1 2.14 1.23E+02 0.28 Unknown impurity
2 4.62 1.87E+02 0.43 Unknown impurity
3 5.82 4.31E+04 99.05 BPC-157
4 8.37 1.06E+02 0.24 Unknown impurity
Bacterial Endotoxin Test (USP <85>)
Method Result Specification Verdict
Kinetic LAL (USP <85>) < 0.125 EU/mL ≤ 0.125 EU/mL PASS
Elemental Impurities (USP <233> / ICH Q3D)
Element Method Result (ppm) Limit (ppm) Verdict
Arsenic (As) ICP-MS < 0.001 2.1 PASS
Cadmium (Cd) ICP-MS < 0.001 0.5 PASS
Lead (Pb) ICP-MS < 0.001 0.5 PASS
Mercury (Hg) ICP-MS < 0.001 3.0 PASS

Note: Peptide samples may contain counter-ions (TFA, acetate) and excipients (mannitol, sucrose) used as lyoprotectants and pH buffers. These are not detected by UV and are not classified as impurities under USP <233>.

Analysis Performed by
Dr. M. Chen, Ph.D. (Analytical Chemistry)
Senior Analytical Chemist · Nexus Molecular Labs
info@nexusmolecularlabs.com
2025-05-07