N NEXUS MOLECULAR LABS ANALYTICAL SERVICES ISO/IEC 17025 Accredited · CAP Certified · Health Canada Licensed

Certificate of Analysis

AOD-9604 (5mg)

Report No: NML-AOD9604-260609-001 Analysis Date: 2026-06-24 Report Issued: 2026-06-28
Sample Identification
Compound AOD-9604 (5mg) Client Numira Peptides  ·  numira.cc
CAS Number221231-10-3Date Received2026-06-20
CompositionMulti-component peptide fractionDate Tested2026-06-24
Molecular Weight 1817.1 g/mol PubChem CID9941957
Lot Number NML-AOD9604-260609 Test Methods HPLC-UV · ICP-MS · Kinetic LAL
Appearance White lyophilised powder Date Reported 2026-06-28
HPLC-UV Purity & Content Analysis
5mg
Ordered Amount
4.95mg
Measured Amount
99.15%
Purity (HPLC-UV)
99.0%
Recovery
Fig. 1 — HPLC-UV Chromatogram (214 nm)  ·  Run: NML_AOD9604_AOD9604-260609_1.d
mAU 0 300 600 900 1200 0 2 4 6 8 10 12 Time [min] AOD-9604 5.63 min
AOD-9604 (5mg) vial
APPEARANCE
#Retention Time (min)Area% AreaAssignment
12.051.1E+020.28Unknown impurity
25.634.010E+0499.15AOD-9604
38.111.1E+020.31Unknown impurity
Bacterial Endotoxin Test (USP <85>)
MethodResultSpecificationVerdict
Kinetic LAL (USP <85>)< 0.125 EU/mL≤ 0.125 EU/mLPASS
Elemental Impurities (USP <233> / ICH Q3D)
ElementMethodResult (ppm)Limit (ppm)Verdict
Arsenic (As)ICP-MS< 0.0012.1PASS
Cadmium (Cd)ICP-MS< 0.0010.5PASS
Lead (Pb)ICP-MS< 0.0010.5PASS
Mercury (Hg)ICP-MS< 0.0013.0PASS

Note: Peptide samples may contain counter-ions (TFA, acetate) and excipients (mannitol, sucrose) used as lyoprotectants and pH buffers. These are not detected by UV and are not classified as impurities under USP <233>.

Analysis Performed by
Dr. M. Chen, Ph.D. (Analytical Chemistry)
Senior Analytical Chemist · Nexus Molecular Labs
info@nexusmolecularlabs.com
2026-06-28